Industry news

Scientific maintenance airflow pulverizer, eliminate the first step

Reading Volume:    Date:2021-08-11

  The development of the powder industry is inseparable from the powder equipment, and the powder equipment, especially the ultrafine pulverized equipment plays an important role in the development of the powder industry. Airflow mill is one of the common ultrafine pulverized equipment, but not all the powder should be smashed with gas flow, which industries will be used?Today,

  Airflow Crusher The role of various types of processing industries is not to be underestimated, but the airflow pulverizer not only gives more and more companies, and improves the work efficiency. Go to objective economic income. Therefore, it has also fully illustrated the importance of the airflow pulverizer, then we should also do it after using the airflow pulverizer to complete the production task, we should also be scientifically maintained the airflow crushing machine. 1. Operating maintenance of the air blower

  Clear the inside of the fan, especially the blade, especially the blade. Add lubricating oil (2 # calcium base grease) in the bearing box. In the fan open, during the operation, if there is an abnormal noise or the body vibration, the body vibration should be stopped immediately.

  2. Host

  Check the wear of grading impeller, spiral feeder, and pulverizing nozzle every twelfth month.

  After 200 ~ 300 hours, it is necessary to clean the powder in the nozzle, the inner wall of the cavity and the grading wheel to prevent the crushing and grading effect. At the pulse valve for 200 ~ 300 hours, the filter bag or exchange must be cleaned. Grading motor bearing lubrication. When the operation of 2000 hours, the molybdenum sulfide grease must be added properly, and there is not much to add too much, otherwise the bearing temperature is increased.

  3. Planet Open Valve

  During the operation of this unit, if you find an abnormal sound, you should stop immediately check. Clean an impeller and body in the body every three months. Fill a 00 # extreme pressure lithium nipide every three months.

  4. Operation and maintenance of pulse bag filter

  The solenoid valve operates in the operating environment, checks once every three months, and cleans the dust. Check the complete situation of the filter bag every six months and replace it. If the air outlet is running, if there is a routing, it should check if the filter bag is detached and broken. Whether the frame presses loose, the gasket is aging, and replaced. The pulse controller and solenoid valve check whether it can work properly before booting.

  5. Control cabinet

  The control cabinet pays attention to dustproof, and the control cabinet door is tightened to prevent dust from entering. Purifying dust by trachea every half a monthEmperor, preventing adverse contact.

  ALPA Powder Technology With an open gesture, the new trend of current artificial intelligence development, the new opportunities of gestation, realizing the industrial powder equipment manufacturing industry and artificial intelligence, the deep integration of the Internet of Things, further promoting industries The overall jump of the powder equipment manufacturing industry.